Comparing Beerkan infiltration tests with rainfall simulation experiments for hydraulic characterization of a sandy-loam soil - Ecole Nationale des Travaux Publics de l'Etat
Article Dans Une Revue Hydrological Processes Année : 2017

Comparing Beerkan infiltration tests with rainfall simulation experiments for hydraulic characterization of a sandy-loam soil

Résumé

Saturated soil hydraulic conductivity, Ks, data collected by ponding infiltrometer methods and usual experimental procedures could be unusable for interpreting field hydrological processes and particularly rainfall infiltration. The Ks values determined by an infiltrometer experiment carried out by applying water at a relatively large distance from the soil surface could however be more appropriate to explain surface runoff generation phenomena during intense rainfall events. In this study, a link between rainfall simulation and ponding infiltrometer experiments was established for a sandy‐loam soil. The height of water pouring for the infiltrometer run was chosen, establishing a similarity between the gravitational potential energy of the applied water, Ep, and the rainfall kinetic energy, Ek. To test the soundness of this procedure, the soil was sampled with the Beerkan estimation of soil transfer parameters procedure of soil hydraulic characterization and two heights of water pouring (0.03 m, i.e., usual procedure, and 0.34 m, yielding Ep = Ek). Then, a comparison between experimental steady‐state infiltration rates, isR, measured with rainfall simulation experiments determining runoff production and Ks values for the two water pouring heights was carried out in order to discriminate between theoretically possible (isR ≥ Ks) and impossible (isR < Ks) situations. Physically possible Ks values were only obtained by applying water at a relatively large distance from the soil surface, because isR was equal to 20.0 mm h−1 and Ks values were 146.2–163.9 and 15.2–18.7 mm h−1 for a height of water pouring of 0.03 and 0.34 m, respectively. This result suggested the consistency between Beerkan runs with a high height of water pouring and rainfall simulator experiments. Soil compaction and mechanical aggregate breakdown were the most plausible physical mechanisms determining reduction of Kswith height. This study demonstrated that the height from which water is poured onto the soil surface is a key parameter in infiltrometer experiments and can be adapted to mimic the effect of high intensity rain on soil hydraulic properties.
Fichier principal
Vignette du fichier
Di%3bBagarello%3bLassabatere%20-%20Comparing%20Beerkan%20infiltration%20tests%20with%20rainfall%20simulation%20experime....pdf (975.68 Ko) Télécharger le fichier
Origine Fichiers éditeurs autorisés sur une archive ouverte

Dates et versions

hal-01719881 , version 1 (05-12-2024)

Identifiants

Citer

Simone Di Prima, Vincenzo Bagarello, Laurent Lassabatère, Rafael Angulo-Jaramillo, Inmaculada Bautista, et al.. Comparing Beerkan infiltration tests with rainfall simulation experiments for hydraulic characterization of a sandy-loam soil. Hydrological Processes, 2017, 31 (20), pp.3520 - 3532. ⟨10.1002/hyp.11273⟩. ⟨hal-01719881⟩
129 Consultations
0 Téléchargements

Altmetric

Partager

More